AC WITHSTAND VOLTAGE |
Output Rating | 5KVAC / 100mA Constant 500VA |
Range | Resolution | Accuracy |
Output Voltage ACV | 0 - 5000 | 1 | ±(2% of setting + 5V) |
Output Frequency | 50Hz / 60Hz ± 0.1% User Selectable |
Output Waveform | Sine Wave THD. < 2% (Resistive Load) Crest Factor = 1.3 - 1.5 |
Output Regulation | ± (1% of output + 5V) From no load to full load |
SETTINGS |
Hi-Limit AC Current mA | 0 - 99.99 | 0.01 | ±(2% of setting + 3counts) |
Lo-Limit AC Current mA | 0 - 9.999 | 0.001 | ±(2% of setting + 3counts) |
Ramp Time second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) |
Dwell Time second | 0 0.3 - 999.9 (0=continuous) | 0.1 |
Arc Detection | The range is from 1 - 9 (9 is the most sensitive) |
AC Current Offset mA | 0 - 2.000 or Auto Set |
DC WITHSTAND VOLTAGE (74517452 ONLY) |
Output Rating | 6KVDC/9999µA |
Output Voltage DCV | 0 - 6000 | 1 | ±(2% of setting + 5V) |
Output Ripple | < 5% (6KV / 9999μA at Resistive Load) |
SETTINGS |
Hi-Limit DC Current µA | 0 - 9999 | 1 | ±(2% of setting + 3counts) |
Lo-Limit DC Current µA | 0 - 999.9 | 0.1 | ±(2% of setting + 3counts) |
Ramp Time second | 0.1 - 999.9 | 0.1 | ± (0.1% of setting + 0.05s) |
Dwell Time second | 0 0.4 - 999.9 (0=continuous) | 0.1 |
Arc Detection | The range is from 1 - 9 (9 is the most sensitive) |
DC Current Offset µA | 0 - 200.0 or Auto Set |
Ramp High Current | ON / OFF User Selectable |
Charge - Low Current µA | 0 - 350.0 or Auto Set |
Discharge Time | ≦ 200 msec |
INSULATION RESISTANCE |
Output Rating | 1KVDC/9999MΩ |
Output Voltage DCV | 100 - 1000 | 1 | ±(2% of setting + 3V) |
Hi-Limit Resistance MΩ | 0 1 - 9999 (0=OFF) | 1 | 100 - 499V 1 - 999.9 ± (8% of setting + 2counts) 500 - 1000V 1 - 999.9 ± (2% of setting + 2counts) 1000 - 9999 ± (8% of setting + 2counts) |
Lo-Limit Resistance MΩ | 1 - 9999 | 1 |
Delay Time second | 0 0.5 - 999.9 (0=continuous) | 0.1 | ± (0.1% of setting + 0.05s) |
Charge - Low Current μA | 0 - 3.500 or Auto Set |
GROUND BOND (7452 ONLY) |
Output Rating | 30A / 600mΩ 8V |
Output AC Current A | 3.00 - 30.00 | 0.01 | ± (2% of setting +2 counts) |
Output AC Voltage V | 3.00 - 8.00 | 0.01 | ± (2% of setting +3 counts) |
Output Frequency | 50Hz / 60Hz ± 0.1% User Selectable |
SETTINGS |
Hi-Limit Resistance mΩ | 0 - 150 (3 - 30A) | 1 | ± (2% of setting +2 counts) |
Lo-Limit Resistance mΩ | 0 - 600 (3 - 10A) |
Lead Resistance Offset mΩ | 0 -200 | 1 | ± (2% of setting +2 counts) |
Dwell Time second | 0 0.5 - 999.9 sec (0 = continuous) | 0.1 | ±(0.1% of setting + 0.05s) |
MEASUREMENT |
AC/DC Voltage KV | 0 - 6.00 | 0.01 | ± (1.5% of reading ) > 500V ± (1.5% of reading + 1 count) < 500V |
DC Voltage V (IR) | 100 - 1000 | 1 | ± (1.5% of reading + 3V) |
AC Current Range mA | 0-3.500 | 0.001 | ±(2% of reading + 3counts) |
3.00-99.99 | 0.01 | ±(2% of reading + 6counts) |
DC Current Range µA | 0-350.0 | 0.1 | ± (2% of reading + 3counts) |
300 - 3500 | 1 | ± (2% of reading + 2counts) |
3000-9999 | 10 | ± (2% of reading + 6counts) |
AC Current A (GB) | 0 - 35.00 | 0.01 | ±(2% of reading + 2counts) |
Resistance MΩ(IR) | 1 - 9999 (Auto Range) | - | 100 - 499V 1 - 999.9 ± (8% of reading + 2 counts) 500 - 1000V 1 - 999.9 ± (2% of reading + 2 counts) 1000 - 9999 ± (8% of reading + 2counts) |
Resistance mΩ(GB) | 0 - 600 | 1 | ±(2% of reading+2counts) |
GENERAL |
Input Voltage AC | 100V / 115V / 200V / 230Vac ± 15% 50Hz / 60Hz ± 5% max. current 15A |
PLC Remote Control | Input : Test Reset Memory1 2 3 |
Output : Pass Fail Processing |
Memory | 50 memories 8 steps / memory |
Disy | 20×2 LCD with back light |
Key Lock | To prevent unauthorized alteration of the test Parameters |
Calibration | Build-in software and external calibrated meters |
Alarm Volume Setting | Range: 0-9 ;0=OFF 1 is softest volume 9 is loudest volume. |
Rear Panel Output | YES | YES | YES |
Built-in Scanner | - | - | - |
External Scanner | - | YES | YES |
Smart GFI | YES | YES | YES |
Analog Meter | YES | YES | YES |
RS232 Interface | YES*1 | OPTION | OPTION |
GPIB Interface | - | YES | YES |
Printer Interface | - | OPTION | OPTION |
TUV-GS listed | YES | - | YES |
CE Compliance | YES | - | YES |
Environment | 0 - 40ºC 20 - 80%RH |
Dimension (W x H x D) mm | 430 x 133 x 400 |
Net Weight | 28Kg | 32Kg |
STANDARD ACCESSORIES |
Power Cord(15A) | ×1 |
Fuses | ×2 (Including a spare contained in the fuse holder) |
Hipot Test Lead 1.5m(1101) | ×1 | ×1 | ×1 |
Hipot Return Lead 1.8m(1102) | ×1 | ×1 | - |
Ground Bond Test Lead 30A 1.5m(1103) | - | - | ×1 |
Ground Bond Return Lead 30A 1.5m(1104) | - | - | ×1 |
*product specifications are subject to change without notice. |